Stewart Ergonomics, Inc., manufactures SLAM DUNK® precision dry leak detectors and No Touch Safety Controls.

SLAM DUNK® is a high performance control, which is easy to master in minutes. Set up consists of following the prompts on the 80-character display and entering simple parameters by pressing the four control buttons. These buttons are password protected to prevent unauthorized changes. Test programs can be linked to run sequentially for parts requiring multiple tests. The test is started by manually or remotely activating the start button. A typical test consists of fill, snapshot, compare and depressurize cycles. A bright red or green LED indicates results of the completed test with +24 sourcing output provided for PLC. Typically, a 7 micron leak in a 15 cu. in. test part can be passed or failed in 5 seconds @ 10 p.s.i., and in a 125 cu. in. test part in 15 seconds at 10 p.s.i. 2 sccm leaks are typically found at 100 p.s.i. in less than 15 seconds at a volume of .6 liters. Vacuum testing down to -14.7 p.s.i. can simplify fixturing of molded parts and is necessary for components of vacuum systems.


 

   Toll Free Phone · 800·323·3164    or call   781·251·9228
   Fax · 781·461·9453
   e-mail · sales@gocfa.com
   Visit Stewart Ergonomics© WebSite