STEWART ERGONOMICS IS PROUD TO ANNOUNCE
IT'S A DIGITAL SLAM DUNK®

· OUTSTANDING FEATURES
· HIGH PERFORMANCE
· LOW COST
· SIMPLE SETUP
· PRESSURE OR PRESSURE AND VACUUM
· EASY TO OPERATE
· WIDE SELECTION OF RANGES
· FAST TEST CYCLES
· 99 PROGRAM STORAGE
· SEQUENTIAL TESTING
Make Your Pressure Testing a SLAM DUNK®

The Clean, Dry Leak Tester

SLAM DUNK® is a high performance control, which is easy to master in minutes. Set up consists of following the prompts on the 80-character display and entering simple parameters by pressing the four control buttons. These buttons are password protected to prevent unauthorized changes. Test programs can be linked to run sequentially for parts requiring multiple tests. The test is started by manually or remotely activating the start button. A typical test consists of fill, dwell, and snapshot, compare and depressurize cycles. A bright red or green LED indicates results of the completed test with +24 sourcing output provided for PLC.

Typically, a 7 micron leak in a 15 cu. in. test part can be passed or failed in 5 seconds @ 10 p.s.i., and in a 125 cu. in. test part in 15 seconds at 10 p.s.i. 2 sccm leaks are typically found at 100 p.s.i. in less than 15 seconds at a volume of .6 liters. Vacuum testing down to -14.7 p.s.i. can simplify fixturing of molded parts and is necessary for components of vacuum systems.


SLAM DUNK® SPECIFICATIONS
· 24 bit A to D Converter senses pressure or vacuum to .00001 p.s.i resolution. · Test program parameters and p.s.i. sense output displays on 4x20 character display.
· Test Time: 1 to 250 seconds, 1 minute to 250 minutes. · User friendly control panel to select, add, change test programs.
· Test Differential Detection: .0001 to 25 p.s.i. · Operator only has to press large start switch to commence testing.
· Dwell Time: 0 to 120 seconds. · Large bright GOOD and BAD L.E.D.s indicate results of test.
· Select pretest pressurization or pressurize at start of test. · Includes remote start input, remote good, bad and test running and E-stop +24V source outputs for automatic testing.
· Snapshot (settle time before sensing): 0 to 25 seconds in .1 sec increments. · AC input power: 120VAC 50/60Hz, fused at 1/2 A.
· Slam test runs concurrently with regular test, reduces good test time 40-60%. · Tester dimensions: 3"H X 19-1/4"W X 4-1/4"D.
· Depressurize duration time: 0 to 99 seconds. · Tester material: Anodized aluminum, NEMA 12 Enclosure.
· Low air time: .2 to 50 seconds. · Dual valve assembly supplied with pressure only units.
· Test program capacity: 99 test programs. · Quadruple valve assembly supplied with pressure/vacuum units.
· Number of test programs links for sequential testing: Up to 98. · Optional precision electronics air pressure regulator automatically sets up selected air pressure 1 year warranty.
· Auxiliary output signals end of good sequential test.  
· 5-digit password protection for changing test programs and papameters.  

MODEL NUMBERS
  1. 132-1010 (.1 to 14.7 p.s.i. pressure)
  2. 132-1030 (1.5 to 100 p.s.i. pressure)
  3. 132-1011 (.1 to 14.7 p.s.i. pressure and -.1 to -14.7 p.s.i. vacuum)
  4. 132-1031 (1.5 to 100 p.s.i. pressure and -1 to -14.7 p.s.i. vacuum)
  5. 132-1050 (5 to 150 p.s.i. pressure)
  6. 132-1080 (6 to 250 p.s.i. pressure)
  7. 132-1051 (5 to 150 p.s.i. pressure and -1 to 14.7 p.s.i vacuum)
  8. 132-1081 (6 to 250 p.s.i. pressure and -1 to -14.7 p.s.i. vacuum)
  9. 132-1070 (15 to 500 p.s.i. pressure)
  10. 132-1090 (20 to 1000 p.s.i pressure)
  11. 132-1071 (15 to 500 p.s.i pressure and -.1 to 14.7 p.s.i. vacuum)
  12. 132-1091 (20 to 1000 p.s.i. pressure and -.1 to 14.7 p.s.i. vacuum)

Call for more Information - (800)-323-3164 or send us email request at sales@gocfa.com